Brisbane Data Centre

Fluccs Dedicated servers are located at NEXTDC’s flagship data centre “B1”. B1 is Queensland’s most fibre-connected commercial data centre, benefiting from the diverse fibre-network infrastructure in the Brisbane CBD. With dual fibre entry ports into the data centre and NEXTDC’s efficient cross connect infrastructure means we benefit from fast connections and reduced latency.

Fluccs Dedicated servers are located at NEXTDC’s flagship data centre “B1”. B1 is Queensland’s most fibre-connected commercial data centre, benefiting from the diverse fibre-network infrastructure in the Brisbane CBD. With dual fibre entry ports into the data centre and NEXTDC’s efficient cross connect infrastructure means we benefit from fast connections and reduced latency.

Robust construction and flood protection
Over 80% of the B1 data centre construction is solid concrete, providing extra security and fire protection while allowing NEXTDC to keep heavy infrastructure on the roof. The elevated Wharf St location has a natural rise, so B1 was well above the peak levels of both the 2011 and 1974 floods.

Advanced cooling technology
The chillers on the roof are made by UNIFLAIR in Italy, chosen because they are the quietest chillers on the market – important for the inner city location.

They have multiple compressors which make them extremely energy-efficient by automatically operating only the minimum number of compressors to achieve the level of cooling required. The chillers have a free air cooling option that provides a base level of cooling on colder days without running any of the compressors – another energy saving measure.

Most of B1’s windows have been sheeted over internally with two layers of fire sheeting (and employ a special water dousing system) to provide greatly increased fire protection from adjacent buildings, as well as added security and insulation from the warm Queensland conditions.

The NEXTDC B1 Data centre provides redundancy, reliability, stability & performance, to create the best Australian location to host your server.

Power Specifications

  • Available power of 5Mva
  • It load capacity of approximately 2.25Mw
  • Minimum N+1 redundancy
  • Dual underground 11kv energex feeders from city power grid once complete
  • N+1 redundant 11kv/415v 2500kva distribution transformers
  • N+1 redundant 1.2Mw UPS modules for data centre load
  • 100% standby generator power (cummins v16 60 litre quad turbo diesel with 2.25Mva output) with N+1 redundancy
  • Full N+1 main electrical infrastructure extending to N+N at PDU level
  • Diverse path vertical distribution cabling to data centre floors
  • Diverse a + B + c power supply distributed at 400v via UPS
  • Minimum 12 hours’ onsite fuel supply

Controlled Environment

  • Minimum N+1 Redundancy for Air Conditioning
  • Air Cooled APC FM40 Air Conditioning Units (N+1)
  • Temperatures Maintained at 22ºC (+/- 2ºC)
  • Humidity Maintained at 50% (+/- 10%)
  • Environmental Monitoring

Fire Detection and Suppression

  • argonite inert gas fire suppression system
  • leak detection systems
  • Distributed fire alarm control equipment to avoid single point of failure
  • Two monitored fire escapes
  • External water sprinkler system to protect from neighbouring building fires
  • Water misting system to protect generators from fire
  • Fully addressable analogue fire alarm system compromising Fire indicator Panel (FiP), mimic panels, heat detection and aSDs systems

Data Centre Security

  • Individual credential checks prior to authorisation
  • 24/7 onsite security personnel
  • Biometric fingerprint security for data centre access
  • anti-cloning access card encryption
  • Secure lifts between floors with man trap entrance points
  • Intruder-resistant glass, steel mesh and solid concrete walls
  • Extensive coverage of motion sensitive cctv cameras
  • Monitoring of news and weather for external security risks